BASIC OPERATION
3-24
CP2000-X User Manual
020-100031-01 Rev. 1 (03-2009)
ADVANCED / PREFERENCES MENU:
As shown below, the Preferences menu provides
access to all test patterns as well as certain system parameters. See Table 3.7 for a
complete description.
Figure 3.12. Advanced: Preferences Menu Functions
Table 3.6. Summary of Advanced Preferences Menu Functions
ADVANCED / PREFERENCES MENU OPTIONS
Test Patterns Display an RGB 12-bit test pattern, or turn patterns off. Always turn OFF
to resume normal operation.
Full Screen Enter a checkmark to display test patterns in full 2048 x 1080
resolution. Clear the checkbox to work with cropping controls for
screen size and shape as desired. Note changes are temporary, i.e.
applied for the current test pattern only. This control is not used for
sources.
Alarm Triggers Choose which conditions you want to trigger an Alarm Window (in
addition to interlocks and problems with the SSM, I
2
C, or lamp, which
are all permanent triggers). It is recommended that all triggers remain
enabled during normal operation. Disable only in an rare emergencies
when the alarm appears to be malfunctioning without real errors.
Lamp Limit Enter the #hours (0-5000) that are expected for this lamp, typically no
more than the number of hours covered under warranty.
Expiry Message Enter a checkmark so that a Lamp Expiry Message will appear on the
TPC when the lamp reaches its defined Lamp Limit.
Language Choose English or Chinese TPC menu text for next re-boot.
System Calendar & Clock Reset the system date/time as desired. Select the desired component
(date/hour/minute/second) and adjust. Save (restart) with “Set” button.
* Screen Saver Enable/disable a TPC screen saver, and set its start-up delay.
*
NOTE:
To use a unique screen saver, a user-defined .bmp must be downloaded to the TPC, replacing the default.
ADVANCED / LAMP MENU:
As shown in Figure 3.13, the Lamp menu provides
controls for optimizing lamp alignment (LampLOC), maintaining a specific light
output over time (LiteLOC), or setting a precise power level for the lamp. Two read-
only areas display related lamp performance details—the side bar graph represents
the current light output and, if LiteLOC is enabled, a heavy line shows the chosen
LiteLOC setting. In addition, the New Lamp button activates a window for entering
the serial number of a newly installed lamp. This button is also available with an