ASCII MESSAGES
B-2
CP2000-X User Manual
020-100031-01 Rev. 1 (03-2009)
Function Code / Examples
Description and Parameters
3 = 4:4:4 packed, 12-bit color
If cinema dual link (A and B):
0 = 4:2:2 packed, 10-bit color with O/E pixels (default)
1= 4:2:2 packed, 10-bit color with O/E lines
2 = 4:2:2 packed, 12-bit color with O/E pixels
3 = 4:2:2 packed, 12-bit color with O.E lines
4 = 4:4:4 unpacked, 10-bit color
5 = 4:4:4 packed, 10-bit color, mixed
6 = 4:4:4 packed, 10-bit color, O/E pixels
7 = 4:4:4 packed, 12-bit color
If DVI port:
0 = Unpacked, 8-bit color (default)
1 = Packed, 10-bit color
2 = Packed, 12-bit color
Data Logging (DLG)
(DLG 1)
(DLG?)
(DLG!002)
0 = Minimum logging of activities—i.e., for errors only
1 = Standard logging (errors plus select operations)
2 = All activities are logged
Error Message Enable (EME)
(EME 1)
(EME!001)
Enable error messages sent via Ethernet, where 0=
disabled and 1= enabled. See ERR.
Error Messages (ERR)
(ERR!010)
Generated for projector errors. Provides error code, error
type, and text explanation.
1 = System error (crash)
]]
2 = System warning (system errors)
3 = Invalid parameter
4 = Too many parameters
5 = Too few parameters
6 = Source does not exist
7 = Could not be executed
8 = Checksum error
9 = Unknown request
10 = Serial communication error
]]
System warnings contain additional parameters. See
Messages With Multiple Parameters
in this Appendix
For Your Information (FYI)
FYI
A change in projector status generally broadcast from
TPC/proj. to all clients. See
Messages With Multiple
Parameters
in this Appendix.
Gamma (GAM)
(GAM!”gamma2.6”)
The “filename” representing the current gamma. For
example, “gamma2.6” is typically used in theatres.
Gamma files (name and content) are all currently pre-
defined. Also known as “look-up tables”.
History (HIS)
(HIS!003 01258 “ABC-1”
00500 “03/05/23 18:23”)
Lamp history describes lamps used in the projector. See
Messages With Multiple Parameters
in this Appendix.
Internal Test Pattern (ITP)
(ITP “RGB-12Bbit-Split Ramp”)
(ITP””)
Enter “test pattern filename” to display this pattern.
Enter “” to turn off the test pattern.
Lamp Changed (LPC)
(LPC “123456”)
Records the serial number of the newly installed lamp,
thus resetting the lamp time to “0” for logging time.
(LPC?)
What lamp is installed?
(LPC!”123456”)
The current lamp is serial# 123456
Lamp Hours of Use (LPH)
(LPH 0528)
The #hours logged on the current lamp (0-9999).