BASIC OPERATION
3-8
CP2000-X User Manual
020-100031-01 Rev. 1 (03-2009)
A simple design with familiar menu icons enables a novice user to display an
accurate and fully optimized image by pressing a single button on the touch-screen,
while protecting precisely configured presentations from accidental or unauthorized
change.
TRAINED OPERATORS, ADVANCED USERS, ADMINISTRATORS and INSTALLERS:
In
addition to the basic user rights shown in the “Any User” above, the TPC offers four
distinct password-protected levels of use (shown in shaded areas in Figure 3.2). Each
has all of the rights of lower levels, plus additional rights as described below:
Trained Operators
can also access the
New Lamp
function required when
replacing the lamp.
Advanced
users
can access two additional menus (
Custom
and
Advanced
) where
they can define all display setups and set the DVI processing path, configure 3D
displays, optimize light output, record lamp changes, activate test patterns and set
certain system preferences.
Administrators
can also use four
Admin
submenus—
Source
,
Screen
, color
Gamut
and
IP Config
—to define setup files as selectable choices for processing a variety
of incoming signals.
Source
files set incoming resolution, offset (rare) and
desired final aspect ratio,
Screen
files determine image cropping (masking), size
of display area, and type of lens, and color
Gamut
information ensures color
display standards are properly met in the current environment. In the
IP Config
menu, the administrator can define new Ethernet settings (IP network addresses)
for the projection head and TPC.
Installers
and other service personnel can access two additional configuration
menus (
General,
and
Lamp)
as well as three more
Status
submenus (
Server
,
Diag
and Interrogator
). The installer can define system operating parameters such as
which projector is controlled by the TPC, and critical lamp parameters such as
installed lamp type, fan speed and light level at the screen. Installers can also
establish temperature scale preference, remote access rights, test pattern access
rights, and extent of data logging. An installer can see ID and error information
for servers, as well as a detailed diagnostics log for in-depth troubleshooting.
When the
CP2000
powers up, the
Touch Panel Controller
will begin the steps of
Initializing…
,
Attempting to log on…,
and
Updating status
, displaying its progress on
the TPC status bar at the bottom of the screen. When initializing is complete, all files
are refreshed on the TPC and the system is in a ready-to-use default operating mode:
The
Main
menu appears on the
Touch Panel Controller,
where you can press the
lamp button to turn on the lamp.
The most recently used channel button is depressed (darkened). Upon turning on
the lamp, the image will appear.
If the TPC fails to initialize and instead displays a communication error such as
No
connection
or
Cannot locate Ethernet port
or
Waiting to Connect
, there is likely a
bad connection or address between the TPC and the rest of the projector. Check that
TPC cabling is intact, and try again. Review
Section 7, Troubleshooting
and, if the
problem persists, contact your network administrator.
TPC
Power-Up Defaults
Failed TPC Connection