INSTALLATION & SETUP
2-4
CP2000-X User Manual
020-100031-01 Rev. 1 (03-2009)
HEAD-TO-AC:
Connect the
Christie-supplied IEC 320
(220V) 15-amp line cord to a
single phase 208V AC
supply.
Do not substitute
other cords.
Input power
required is 200 - 240 VAC
(±10%), 50 to 60 Hz @ 3
amps for 208 V.
WARNING
Do not attempt operation if
the AC level is not within
the specified voltage and
power range for the
projection head
(180-265 AC).
EXTRACTOR:
Also plug the extractor fan into the projector. See
2.4, Installing a Lens,
Lamp, & Cooling
At this point, the projection head is ready for use:
The voltmeter should display the incoming voltage
PROJ.
STATUS
light should be green
Light engine compartment fans near the front should be running
Remainder of projection head will be off
Set Lamp Type and Cable Length
NOTE:
Service/installer required
.
WARNING
Explosion hazard. Keep the projection head
OFF
until
you have defined which lamp type is installed.
Figure 2.5. Connecting Projection Head
to AC Supply
STEP 6