MAINTENANCE
6-10
CP2000-X User Manual
020-100031-01 Rev. 1 (03-2009)
Check Leads
Make sure that the anode (+) lead between lamp and igniter is well away from any
projector metal such as the reflector or firewall.
WARNING
Leads too close to metal parts will cause arcing during
starting pulse. This is a SAFETY HAZARD,
and the lamp may not ignite.
Close cooling compartment and lamp door
The projector will not operate unless the louvered door is locked shut.
Record the LAMP INSTALLED
With a blue dot label or dry-erase pen, mark the lamp door’s LAMP INSTALLED
label (Figure 6.3) to indicate the size of the newly installed lamp — 2.0, 3.0, 4.5, or
6.0 kW. A supply of blue dot labels is secured inside the front cover of this manual.
Figure 6.3. Always Mark the “Lamp Installed” Label
(EXAMPLE)
Re-connect to AC and turn breaker to ON
Re-connect the projection head and the ballast to AC (see
2.1, Quick Setup
), then set
the ballast breaker to
ON
.
Set proper LAMP TYPE (power)
NOTE:
Skip this step if your new lamp is the same size as the old lamp—the Lamp
Type will still be correct in the
Install
menu.
IMPORTANT:
Requires access to TPC
Install: Lamp
menu (authorized access only).
If your new lamp is larger or smaller than the old lamp, record the new lamp type
(2.0, 3.0, 4.5 or 6.0 kW) in the
Touch Panel Controller
’s
Install: Lamp
menu
before
igniting the new lamp
. This setting establishes the proper range of power available
for the installed lamp, ensuring that the new lamp is neither underpowered nor over-
driven.
STEP
9
STEP
10
STEP
11
STEP 12
STEP 13
Summary of Contents for CP2000-X
Page 1: ...CP2000 X U S E R M A N U A L 020 100031 01...
Page 2: ......
Page 42: ......
Page 102: ......
Page 112: ......
Page 130: ......
Page 135: ...SPECIFICATIONS CP2000 X User Manual 8 5 020 100031 01 Rev 1 03 2009...
Page 160: ......