ASCII MESSAGES
CP2000-X User Manual
B-7
020-100031-01 Rev. 1 (03-3009)
Component Code (P3)
Component
0031
SSM, Upgrade Failed
0040 Initialization
Failed
0041
Power-up Self-test Failed, Reset Engine
0042
RDRAM Init Status
0043
Get Vertical Frequency Failed, 12C Error
0044
12C Communication Failure
Examples of Critical System Error (001) Messages
(65535 01002 ERR 001 “System Error: 0008 00001 Fan, Intake 1”)
(65535 01002 ERR 001 “System Error: 000A 00001 Fan, Card Cage)
(65535 01002 ERR 001 “System Error: 0021 00001 Lamp, Failed to Ignite”
Table B.4. P3 Codes for “002” System Warning” Error Messages
Component Code (P3)
Component
8010
Prism, Temperature Warning
8011
Temperature, DMD Red
8012
Temperature, DMD Blue
8013 Temperature,
Integrator
8014 Temperature,
SSM
8015
Temperature, Card Cage
8016 Temperature,
Ballast
8020
Lamp, Life Expired
8021
Lamp Failed to Ignite
8032
SSM Read Failed
8033
SSM Flash Write Attempted
8034
Motor Calibrate Failed
NOTE: System Warning messages can elevate to System Error messages if the
problem is not fixed. In these cases, the “8” in the original System Warning code will
change to a “0” (see Table B.3).
Table B.5. P4 Codes
(INCLUDED WITH SYSTEM WARNING ERROR MESSAGES ONLY)
Examples (P4)
Meaning
1500 (or lower)
Fan speed is 1500 RPM. Speed must be 1501 RPM or higher.
056 (always °C)
Temperature is 56°. Cool to within ranges shown in
Table 3.1
.
00001
There is no P4 data for this type of error
Examples of System Warning (002) Error Messages
(65535 01002 ERR 002 “System Warning: 8010 00051 Prism, Temperature Warning”)
(65535 01002 ERR 002 “System Warning: 8020 00001 Lamp, Life Expired”)
(65535 01002 ERR 002 “System Warning: 8032 00001 SSM Read Failed”)