"Bowl unit temperature rise problem!"
After 5 minutes' calibration, bowl unit
T° < 90% of the setpoint)
■
Confirm on the maintenance screen.
■
Cooling too intense:
- Test the solenoid valve on the maintenance
screen and observe its draining efficiency; if
the solenoid valve is jammed, replace it
- Check water flow and if necessary adjust
the flow rate.
■
Insufficient heating:
- Check the heating circuit
- If necessary, replace the faulty resistor(s).
op. 12-7
op. 12-13
op. 2-1
ERR 13
"Bowl unit still hot!"
10 minutes after the end of the test
Bowl unit T° > setpoint T° or 30°C
if setpoint T° > 50°C
■
Confirm on the maintenance screen.
Problem on the cooling circuit
- The feed water is too hot: correct
- No outflow:
check the water connection, check that the
solenoid valve is working (on the
maintenance screen), adjust the flow rate.
If the circuit is blocked up, locate the
blockage by dismantling parts one by one.
■
Incorrect temperature reading:
- Recalibrate bowl unit temperature
measurement.
- Replace the sensor if the problem persists
op. 12-2
op. 2-2
ERR 15
"Bowl still hot!"
10 minutes after the end of the test,
bowl thermocouple T° still > 50°C (his
may be a thermocouple problem)
■
Confirm on the maintenance screen.
Problem on the cooling circuit
- The feed water is too hot: correct
- No outflow:
check the water connection, check that the
solenoid valve is working (on the
maintenance screen), adjust the flow rate.
If the circuit is blocked up, locate the
blockage by dismantling parts one by one.
■
Incorrect temperature reading:
- Recalibrate bowl temperature
measurement.
- Replace the bowl thermocouple if the
problem persists
op. 12-7
op. 12-2
op. 2-3
ERR no.
Display/Description
Action
See
Chap.3 §
Summary of Contents for Mixolab 2
Page 2: ......
Page 4: ......
Page 6: ...Mixolab 2 6 Maintenance manual 09 2016...
Page 8: ...8 Maintenance manual 09 2016 Mixolab 2...
Page 15: ...15 Maintenance manual 09 2016 Mixolab 2 Chapter 2 TROUBLE SHOOTING...
Page 16: ...16 Maintenance manual 09 2016 Mixolab 2...
Page 30: ...30 Maintenance manual 09 2016 Mixolab 2 Chapter 2 Trouble shooting...
Page 31: ...31 Maintenance manual 09 2016 Mixolab 2 Chapter 3 REPAIRS...
Page 32: ...32 Maintenance manual 09 2016 Mixolab 2...
Page 38: ...38 Maintenance manual 09 2016 Mixolab 2 Chapter 3 Repairs...
Page 39: ...39 Maintenance manual 09 2016 Mixolab 2 Chapter 3 Repairs 2 Instructions See following pages...
Page 112: ...112 Maintenance manual 09 2016 Mixolab 2 Chapter 3 Repairs...
Page 113: ...113 Maintenance manual 09 2016 Mixolab 2 Chapter 4 SPARE PARTS...
Page 114: ...114 Maintenance manual 09 2016 Mixolab 2...
Page 116: ...116 Chapter 4 Spare parts Maintenance manual 09 2016 Mixolab 2...
Page 134: ...134 Chapter 4 Spare parts Maintenance manual 09 2016 Mixolab 2...