7.5.12 Dehumidifier management
To adjust ambient humidity, a dehumidifier can be used. Dehumidifier control is possible only during Cooling mode.
If dehumidification is required, then its possible to control the dehumidifier through a relay connected between
Terminal 45-N.
The dehumidifier managed with humidity sensor. A demand for dehumidification occurs only in Cooling mode.
Parameters
Level
Parameter
Function description
Display & Input value
Remarks
Group Code
Default
min.
Max.
Unit
I
51
17
T erminal 17-18 : Humidity sensor
0=disable
1=enable
0
0
1
-
I
51
45
T erminal 45 : Dehumidifier
0=disable
1=enable
0
0
1
-
PCB(Terminal)
230V 50Hz
Dehumidifier
Neutral
EHS
45
46
47
48
49
N
41
42
43
44
Electric
heater
Heating
Cooling
mode
output
Alarm
Pump1
Pump2
Dehumidifier
Humidity sensor
17
18
Humidity
Sensor
COM
89
7. Unit Management
Summary of Contents for AEYC-0639U-CH
Page 156: ...20810030 M ...