7.5.7 Additional water pump
7.5.7.1 Additional water pump1
A parameter can be used to set the desired operation:
- Additional water pump1
- Additional water pump2
A parameter can be used to set the desired type of pump operation, as follows:
Depending on Main water pump setting
Depending on Main water pump setting but always OFF when the DHW mode is activated
Always ON, apart from if any alarms are active or if the HP unit is in OFF mode
ON/OFF based on Room air temperature (set by Remote controller)
Note: As for the above sentence No. , “OFF mode” means Power supply for HP unit is ON, and with no
operation for Heating/Cooling/DHW.
Parameters
Level
Parameter
Function description
Display & Input value
Remarks
Group Code
Default
min.
Max.
Unit
I
51
48
T erminal 48 : Pump1
0=disable
1=1st Additional water pump1 for Zone1
0
0
1
-
I
51
49
T erminal 49 : Pump2
0=disable
1=1st Additional water pump1 for Zone1
0
0
1
-
Additional water pump1
230V 50Hz
P
PCB(Terminal)
Dehumidifier
Neutral
EHS
45
46
47
48
49
N
41
42
43
44
Electric
heater
Heating
Cooling
mode
output
Alarm
Pump1
Pump2
Parameters
Level
Parameter
Function description
Display & Input value
Remarks
Group Code
Default
min.
Max.
Unit
I
51
48
T erminal 48 : Pump1
0=disable
1=1st Additional water pump1 for Zone1
0
0
1
-
I
42
20
T ype of operation of additional water pump
0=disable
1=depending on Main water pump setting
2= depending on Main water pump setting but always
OFF when the DHW mode is activated
3= always ON, apart if any alarms are activated or if
the HP unit is in OFF mode
4=ON/OFF based on Room air temperature
0
0
4
-
80
7. Unit Management