7.4 Frost protection
7.4.1 Frost protection based on Room air temperature
Frost protection can be activated when the HP unit is in OFF mode.
This is controlled based on either the Outgoing water or air temperature:
Frost protection based on Room air temperature
Frost protection based on Outdoor air temperature
Frost protection based on Outgoing water temperature
DHW tank frost protection
Secondary system circuit frost protection
The purpose of this function is to protect the room from freezing when in OFF mode. When active, it uses the
available heat sources configured for normal management of the Heating system (HP unit, alternative heat source).
Note1: The HP unit will operate based on the Frost protection set point, if this shuts down (high pressure switch
activation, shut down due to heat exchanger Outgoing water temperature etc.), the other available heat
sources will be activated.
Note2: Additional water pumps 1 and 2 are tuned “ON” together with the main pump.
Parameters
Level
Parameter
Function description
Display & Input value
Remarks
Group Code
Default
min.
Max.
Unit
I
43
01
Start temperature of Frost protection on Room air
temperature
14.0
0.0
40.0
0.5°C
I
43
02
Hysteresis of Room air temperature of Frost protection
1.0
0.5
5.0
0.5°C
I
43
03
Water temperature of frost protection
35.0
10.0
60.0
0.5°C
I
43
04
Delay time OFF main pump from OFF Frost protection
operation function
30
0
120
1sec
(1.0°C)
(14.0°C)
Start temperature
hysteresis
Water pump deactivation
Room air temperature
Water pump ON
OFF
68
7. Unit Management