Chapter XI Performance Characteristics Test
170
synthesized signal generator 1464C.
2)
Set the output power level frequency of the signal generator to -13dBm and the output frequency to 100
MHz.
3)
Press
【
Preset
】
on the spectrum analyzer, and set it as follows:
Center frequency .............................................................................................................................. 100 MHz
Span .................................................................................................................................................... 100 Hz
Reference level ................................................................................................................................. -10 dBm
Attenuation ............................................................................................................................................. 0 dB
Resolution bandwidth ........................................................................................................................... 10 Hz
4)
Wait for completion of the new sweep, and press
【
Peak
】
,
【
Marker
】
and [Detla]. In this case, the attenuator
attenuation value at 0 dB can be made as a reference.
5)
Set the spectrum analyzer; press
【
Ampt
】
[Attenuation Automatic Manual], and set the attenuation value of
the attenuator according to the test form.
6)
After the sweep is completed, press
【
Peak
】
, and the amplitude of the current differential marker is the
attenuator switching error.
7)
Repeat steps 5-6 until the test of all the attenuation values of the attenuator is completed, and then record the
test result in the
4041 Series Spectrum Analyzer Record Sheet
.
11.18 Input voltage standing wave ratio test
A) Testing equipment
Network analyzer N5245A
A set of 2.4 mm calibration kit (including open circuit, short circuit and load)
2.4 mm (m-m) calibration cable×1
b) Test steps
Summary of Contents for 4041 Series
Page 1: ...4041 Series Spectrum Analyzer User Manual China Electronics Technology Instruments Co Ltd...
Page 2: ......
Page 4: ......
Page 5: ......
Page 6: ......
Page 20: ...8 Article I Instructions...
Page 21: ...9...
Page 33: ...Chapter III Basic Operations 21...
Page 125: ...Chapter VIII Channel Scanner Mode Option 113 Fig 8 3 Schematic Diagram of List sweep...
Page 141: ...Chapter IX Field Strength Measurement Mode Option 129...
Page 142: ...130 Article II Technical Instructions...
Page 143: ...Chapter IX Field Strength Measurement Mode Option 131...
Page 184: ...Chapter XI Performance Characteristics Test 172 minimum frequency of 1 Hz and 1 3 steps...
Page 185: ...173 Article III Maintenance Instructions...
Page 186: ...174...