2. Setting up GT-3 Series
11.
Remove the protection film.
12.
Remove the black rubber cap on the edge of the Tube, connect the Tube to the Print Head and fix the
Tube by rotating the Tube Connector by 90 degrees.
13.
Take off the gloves and connect the Flat Cable to the Carriage PCB. Put the Flat Cable with the terminal
(metal) side on the top (left), insert straight into the connector and fix it by pushing the tabs of both sides
(right).
<Important!>
Do not insert the Flat Cable at an angle in installation. The electric current may not be stable and
increase the Print Head temperature, which causes machine errors (e.g. “Head Temp High”), mis-firing,
and give serious damage to the Print Head. Do not repeat the insertion, or the terminal (metal) may be
damaged and may cause serious mis-firing.
Never wet the Connectors or other metal parts; it may short-circuit and damage the printer.