6. Replacing Parts
3.
Hold the Spacer M3-30 with the Open ended spanner: M3 (5.5 mm), and fix it with the four screws (5)
with tightening torque 0.8 N·m.
(5)
4.
Tighten the two screws (6) with tightening torque 0.5 N·m, and mount the Cap Felt (7) facing to the bent
portion of the CL Guide Lower (position A).
(A)
(7)
(6)
5.
Fix the Waste Ink Tube 1 (8) to the Ink Tray (1) with the Band (9) to the end, less than 1 mm margin from
the root.
(1)
(9)
(8)