6. Replacing Parts
6.
Pass the Waste Ink Tube 1 (8) through the Cord Clamp 13-L (10).
(8)
(10)
7.
Insert the Maintenance Middle Tube 2 (12) into the Waste Ink Joint (11) until the Maintenance Middle
Tube 2 can reach to the end, less than 1 mm margin from the root.
(11
(12)
)
8.
Fix the Waste Ink Joint (11) on the Pump Holder (13) with the screw (14), with tightening torque 0.5 N·m,
and insert the Pump Tube (15) and the Joint (16) until to the end, less than 1 mm margin from the root.
(14)
(11)
(16)
(15)
(14)
(13)