6. Replacing Parts
Reduction Belt
1.
Loosen the four Bolt Sockets (1).
2.
Loosen the Nut 2 M4 (2) and adjust the Bolt Socket (3) by checking the tension with the belt tension
meter.
<Note> Move the Platen Arm at the rearmost position and check the tension at the left side of the Belt, by
flipping it with your finger.
・
The tension increases by turning the Bolt Socket clockwise.
・
The tension decreases by turning the Bolt Socket counter-clockwise.
(1)
(2)
(3)
Flipping point
3.
Screw the Nut 2 M4 (2) and the two Bolt Sockets (1), load and unload the Platen by hand to make it move
smooth, and then check the tension again.
<Note> Repeat the steps 1 to 3 if the tension is out of the reference value.
4.
Connect the connector from the Platen Motor to the Main PCB.
GT-3 Series
134