6. Replacing Parts
2.
Mount the Tube Joint VRFE6 (3) with the Tube & Filter Assy made in step 1 in the previous page. Rotate
the Joint by 30-40 degrees where you insert.
(3)
3.
Connect the Tube on the Print Head. Insert the Tube Connector (2) to the Tube; insert the Tube slowly
and straight to the Print Head (left figure). Confirm that the edge of the Tube can reach to the Print Head.
Rotate the Tube Connector (2) by 90 degrees (right figure) to fix the Tube.
(2)
(2)
4.
Turn ON the Printer.
5.
Load the ink to the replaced Tube. (Refer to “2-6-2. Introducing Ink”.)
6.
Print Nozzle Check Pattern to confirm the print quality. (Refer to “2-6-3. Test Print”.)
GT-3 Series
266