6. Replacing Parts
14.
Connect the Pump Tube (3) to the Drain Joint (2).
(3)
(2)
15.
Pass through the Pump Tube at the side of the Frame. Pay attention that the Pump Tube should not
bend around the outlet.
16.
Insert the Pump Holder to the Frame and fix it with the left/right Screws (1) with tightening torque 1.5 N·m.
(1)
(1)
17.
Attach the Covers.
(Refer to “6-1-2. Assembling/Disassembling of the Covers”.)
18.
Adjust the firmware (Tube pump) with GT-3 Service Tool. Refer to the end of “6-1-20.Suction Pump
Assy”.
GT-3 Series
182