3.
Operation
3-1-5-5. Temperature Adjustment
The temperature sensor is mounted on the Carriage PCB to detect the environmental condition. This menu
adjusts the calculation of the temperature sensor.
The temperature sensor has been adjusted in manufacturing but adjust the value when you replace the
Carriage PCB and/or Main PCB.
The temperature is adjustable by 0.5C degree (1F degree), within the ±5C degrees.
3-1-5-6. Solid Print
The Solid Print patterns are available in the printer.
Print this when you confirm the Print Head clogging caused by cracked Tube. You can confirm the banding
issue with this pattern. Refer to “4-1-2. Heavy misfiring in printing (Checking Cracks inside the Tube)”.
The Solid Print pattern is printed almost the full size of 14x16 Platen. Bette to print on T-shirt rather than on
paper, because the ink volume is large and may cause “flood” on the paper.
Example: “Solid K” for Black
3-1-5-7. Log Level
This menu is to confirm the issues. Use it as-is: “Standard Information”. When you are requested by the
manufacturer, select “Detailed Information”, which can record in a very short period of time. Set the menu to
“Standard Information” soon after the necessary log data is exported.
GT-3 Series