6. Replacing Parts
(7)
(D)
2.
Move back the Carriage Back Plate (6) to the original position, and mount it with the four Bolt Socket (3)
and the two Screws (4).
<Note> Take care not to bend or crush the Tubes; they are very fragile.
3.
Mount the Encoder Cover F (2) with the four Screws (1).
4.
Mount the Cover UB and UF. (Refer to “6-1-2. Assembling/Disassembling of the Covers”.)
Adjustment
1.
Execute CR Origin Sensor Adjustment. (Refer to “
3-1-5-1.
CR Origin Sensor Adjustment”.)
2.
If read error occurs, e.g. printing position shift, clean the Encoder Strip. (Refer to “
5-1-5.
Cleaning the
Encoder Strip”.)
GT-3 Series
161