6. Replacing Parts
GT-3 Series
271
4.
Remove the PVC Cap (7) of the needle, insert the Tube Clamp D3 (8) into the Tube, and then insert the
Tube into the Needle. Apply some distilled water around the outside of the Tube to insert the Tube Clamp
smoothly.
<Note>
・
Without distilled water, Tube may move round with Tube Clamp and it may kink.
・
Do not put distilled water INSIDE the tube, the ink may be damaged.
5.
Fix the Tube by screwing the Tube Clamp D3 (8), holding the Tubes softly as shown below.
<Note>
・
If you feel the Tube can rotate together with the Tube Clamp, the tube may kink. Loosen the Tube
Clamp and apply some distilled water first.
・
Insert the Tube and the Tube Clamp D3 until the edge will hit the Nut 8.
6.
Remove the Filter Cartridge (6) and insert the Ink Cartridge (9).
(7)
(8)
(C)
Until the touch the both edges
(6)
(9)