6. Replacing Parts
3.
Tighten the four Bolt Sockets (with tightening torque 6 N·m) so that the clearance of the Maintenance
Unit Check Gauge and the Cap Rubbers should be equal.
4.
Remove the Maintenance Unit Check Gauge.
5.
Move the Carriage to the upper position of the Maintenance Unit.
10 mm
6.
Rotate the CL Cam with a finger and move the Cap Rubbers to the up position.
Additionally rotate the CL Cam to move the Cap Rubbers at the bottom position.
Move the Carriage between the Flushing Plate and the Platen, so that you can see the surface of the
Print Heads.