Installation procedure for flush-front mounting
NOTE
The switch must be turned off and disconnected from the fabric during this procedure.
NOTE
The illustrations in this document show a 1U switch, but the instructions are the same for a 2U switch.
Complete these tasks to install the switch in a four-post rack:
•
on page 42
•
Attaching the extension brackets to the switch
on page 43
•
Installing the switch in the rack
on page 44
•
Attaching the rear brackets to the extensions
on page 45
•
Attaching the rear brackets to the rack posts
on page 46
Attaching the front brackets
Complete the following steps to attach the front brackets to the switch.
1. Position the right front bracket with the flat side against the right side of the switch at the front of the
.
2. Insert four 8-32 x 5/16-in. flathead screws through the vertically aligned holes in the bracket and
then into the holes on the side of the switch. Use the upper and lower screw holes, leaving the
center holes empty.
3. Repeat step 1 and step 2 to attach the left front bracket to the left side of the switch.
4. Tighten all the 8-32 x 5/16-in. screws to a torque of 15 in-lb (17 cm-kg).
Installation procedure for flush-front mounting
42
Brocade VDX 6940 Hardware Installation Guide
53-1003495-02
Summary of Contents for VDX 6940 Series
Page 1: ...53 1003495 02 25 June 2015 Brocade VDX 6940 Hardware Installation Guide ...
Page 6: ...6 Brocade VDX 6940 Hardware Installation Guide 53 1003495 02 ...
Page 14: ...What s new in this document 14 Brocade VDX 6940 Hardware Installation Guide 53 1003495 02 ...
Page 64: ...Verifying operation 64 Brocade VDX 6940 Hardware Installation Guide 53 1003495 02 ...
Page 84: ...Thermal operations 84 Brocade VDX 6940 Hardware Installation Guide 53 1003495 02 ...
Page 106: ...Replacing a transceiver 106 Brocade VDX 6940 Hardware Installation Guide 53 1003495 02 ...
Page 120: ...Germany 120 Brocade VDX 6940 Hardware Installation Guide 53 1003495 02 ...
Page 136: ...136 Brocade VDX 6940 Hardware Installation Guide 53 1003495 02 ...