4-13 – Interior and Exterior Systems Operation – Waste System____________________________M380 Owner’s Manual
4-13-6 Rev. “F”
14-13.8.2 Cleaning
Use Micro-Clean Organic Cleaner, P/N 24542, or other common liquid toilet bowl cleaner for use with
the Microflush toilet. Caustic drain openers or non-biodegradable cleaners should not be used.
1. While depressing the flush activator, turn off the water. Allow the bowl cleaner to flow into the
lower chamber. Keep the flush activator pressed.
2. Insert bowl brush into lower chamber and agitate mixture.
3. Remove the bowl brush and release the flush activator.
4. Turn the water on and flush twice to rinse thoroughly. If used with a Microphor Biological
Waste Treatment System, check manual for acceptable cleaners.
14-13.8.3 Clearing Plugged Toilet
Turn water off; press flush handle and hold to remove water from the bowl. The flapper in the bottom
of the toilet will remain open until the flush handle is released. Check to see if the restriction can be
removed from the hopper with a hooked wire, being careful not to damage the rubber seal on the
flapper or the mating surface on the hopper. If obstruction cannot be picked out with a hook or tongs,
use a plunger by pushing in slowly and pulling out quickly to pull object back into the hopper. If
necessary, turn the air off and use a snake inserted through a 12” plastic pipe placed in hopper. The
pipe will protect the flapper seal from damage. If the Air/Water Sequence Valve will not operate with
the water turned off, hold the flush lever down and turn the water on and off quickly to free the valve
action. When the passage becomes clear, turn the water on and press the flush handle to start the
flush cycle.
14-13.8.4 Winterizing
Shut off water to toilet. Flush toilet three times or until water no longer
flows into the bowl. Unhook water supply at angle stop. Empty water in
line into receptacle. Shut off air supply to the toilet. The unit is now
prepared for freezing temperatures. Open petcocks on drip legs and air
receiver drain after shutting down air compressor and isolating air lines.
4-13.8.5 Cleaning Bleed Off Assembly
Standard Flush
– Remove plug and clean with
solvent; air blow dry.
Positive Flush
– Remove plug and clean with solvent;
air blow dry, remove and clean plug on Detent Valve.
NOTE: Use 5/32” (4mm) Allen wrench to remove
plugs.
Summary of Contents for M380 2003
Page 1: ...Rev F...
Page 375: ...DIRECTV HD RECEIVER USER GUIDE...
Page 377: ...Section Title...
Page 379: ...Section Title 1 2 Welcome 3 About Your User Guide 4 Defining High Definition Chapter 1...
Page 417: ...Section Title Chapter 3 39 40 Watching TV 43 The Guide 45 Autotune 47 Pay Per View Chapter 3...
Page 426: ......
Page 473: ......
Page 476: ......