4-5 – Interior and Exterior Systems Operation – Inverter__________________________________M380 Owner’s Manual
4-5-14 Rev. ”F”
2. Time Left to Run
This meter displays the estimated hours the batteries will support the load
before requiring recharging. The meter is accurate to 1/10 of an hour (6 minutes).
3. Time Left to Charge
This meter displays the estimated hours required to charge the batteries
to full capacity. The meter is accurate to 1/10 of an hour (6 minutes).
4. Set Shore Power
This meter sets the shore power input (from 5-30
amps) so the total current draw from the charger does not
exceed the circuit breaker rating, to provide the maximum
current to the ac loads. Use the Settings push button
(RIGHT arrow) to change this setting to match the circuit
breaker rating of the ac power source.
NOTE: The maximum current draw from the 3000-kVA unit’s charger is 28 amps.
NOTE: This setting does not prevent the loads from exceeding the shore circuit breaker rating.
5. Generator Start/Stop
The generator can be manually started or stopped from this
display by pressing the On/Off push button on the RC7GS front panel.
NOTE: Starting the generator from this display overrides all auto-start/stop function and
displays “Man/Stop Only!” on the User Status menu. Stopping the generator returns the auto
start/stop functions.
Summary of Contents for M380 2003
Page 1: ...Rev F...
Page 375: ...DIRECTV HD RECEIVER USER GUIDE...
Page 377: ...Section Title...
Page 379: ...Section Title 1 2 Welcome 3 About Your User Guide 4 Defining High Definition Chapter 1...
Page 417: ...Section Title Chapter 3 39 40 Watching TV 43 The Guide 45 Autotune 47 Pay Per View Chapter 3...
Page 426: ......
Page 473: ......
Page 476: ......