152
SCAN-LAN VI
Appendix D: Cable Replacement
Procedure
D.1 General
The Modular Plug Performance Module shipped with your SCAN-LAN VI
features a user-replaceable test cord. This Performance Module is a critical
part of a SCAN-LAN VI. The SCAN-LAN VI uses frequencies up to
100 MHz, where 1 inch of wire is a significant part of a wavelength. Proper
wire preparation and pair twisting is extremely important to preserve
measurement accuracy. Follow the procedures carefully including re-
calibration and testing.
D.2 Equipment
C
ABLE
R
EQUIRED
Preferred:
Pre-tested replacement cable from Black Box. These cables
have been tested for Near-End Crosstalk and other critical
parameters and have had wire ends prepared for direct
installation.
Or:
EIA/TIA T568A Category 5 patch cord, 8-ft. length, cut in two
Or:
4-ft. Category 5 patch cord, with one connector removed.
T
OOLS
R
EQUIRED
• Tie wrap—approximately 0.14 inch wide x 3 inch minimum length
(3.6 mm x 7.5 cm)
• Screwdriver—flat blade 0.10 inch (2.5 mm)
• Side-cut pliers (dikes)
• Wire-stripping tool
• Knife.