103
CHAPTER 9: Setup
NOTE
Display contrast can be adjusted as follows:
Hold the backlight button down while pressing the arrow keys, until the
contrast is set for comfortable viewing.
9.2 Changing Setup Parameters
NOTE
Changes to the setup parameters are automatically stored in non-
volatile memory. Setup settings are not lost when replacing batteries.
9.2.1 L
ENGTH
M
EASUREMENT
U
NITS
The Units parameter selects feet or meters for cable-length measurements.
• Switch dial to SETUP.
• Highlight Units using the arrow keys.
• Press FEET/METERS (F4) to change length units.
9.2.2 F
AULT
T
HRESHOLD
Fault Threshold is the minimum reflection level detected as an anomaly in
the Length test. Any reflection less than this threshold will be ignored by
the SCAN-LAN VI.
The default Fault Threshold value is 7%, which corresponds to the worst-
case allowable impedance discontinuity specified in IEEE 802.3 for coaxial
cable. Anomalies that are greater than this threshold may impair network
transmission.