Table A-4. ISO/IEC 11801 Pass/Fail Limits
Frequency
Max. Attenuation Values (dB)
Min. NEXT Loss (dB)
(MHz)
Class C
Class D
Class C
Class D
1
3.7
2.5
39
54
4
6.6
4.8
29
45
10
10.7
7.5
23
39
16
14
9.4
19
36
20
N/A
10.5
N/A
35
31.25
N/A
13.1
N/A
32
62.5
N/A
18.4
N/A
27
100
N/A
23.2
N/A
24
Table A-5. ISO 11801 Class C, Class D ACR Test Limits
Frequency (MHz)
Minimum ACR (dB)
Class C
Class D
1
35.3
—
4
22.4
40
10
12.3
35
16
5
30
20
—
28
31.25
—
23
62.5
—
13
100
—
4
Table A-6. ISO 11801 Class C, Class D Pass/Fail Limits