62
SCAN-LAN VI
Press the down arrow to view Delay Skew test summary. This screen shows the
additional delay time for each pair, compared to the shortest pair.
6.12 Resistance
The Resistance test measures and displays in ohms the DC resistance of each
wire in the cable.
Resistance is a measure of opposition to DC current flow in a cable. DC
resistance can be used to identify poor wire connections, which typically have
large resistance. Loop Resistance can be derived by adding the resistance for
each wire in the pair.
Resistance can be added to the Autotest suite of tests by defining a Custom
Cable standard (see
Appendix A
). Resistance can also be run individually via
SAVE
DELAY SKEW
F1
F2
F3
F4
1,2
8ns
3,6
16ns
4,5
3ns
7,8
0ns
SAVE
DELAY
F1
F2
F3
F4
1,2
494ns
3,6
502ns
4,5
489ns
7,8
486ns