67
CHAPTER 6: Cable Test Descriptions
2. Press PAIR (F1) to display the results for a different wire pair. Press SEND
(F2) to send the results to the remote unit.
3. Press the arrow keys to move the cursor to a new point on the graph. The
test result at the selected point is displayed below the graph.
4. Press Print (F4) to send a comma-separated variable (CSV) listing of the
results to the serial port. This outputs a complete listing of all Power Sum
NEXT measurements for all pairs.
5. Press SUMMARY (F3) or ESC to return to the Summary screen.
NOTE
The test result displayed on the graph is the worst value found within
1-MHz frequency increments for Category 5 and ISO Class D testing. All
test results are available and can be output from the SCAN-LAN VI.
6.14 Cable Grading
The SCAN-LAN VI does not perform cable grading.
PAIR SEND SUMMARY PRINT
F1
F2
F3
F4
1
20
30
40
50
60
1,2
100
43.0dB
@
67.3MHz
32.1
Summary of Contents for SCAN-LAN VI
Page 2: ......