155
APPENDIX D. Cable Replacement Procedure
NOTE
Observe carefully the direction of the wire’s twist. Proper installation
requires this same twist direction right up to the screw terminals. When
viewed from the end, most wire twists clockwise as it approaches the
wire’s end.
3. Arrange the cable and wire pairs as shown in Figure D-2. Do not
untwist the pairs any more than required to strip the wire ends.
4
Cut the two inner wire pairs (orange and blue for EIA/TIA T568B)
to 1
1
⁄
8
inches (28 mm) from the jacket.
5. If using ScTP, cut the bare drain wire to 1 inch (25 mm).
6. Remove insulation
1
⁄
4
inch (6 mm) from the end of each wire and twist
to capture all strands. Optionally, tin the ends to capture all strands.
7. Re-twist each wire pair in their original direction. Use two or three full
twists for the two outer pairs and one or two twists for the two inner
parts.
D.5 Reassembly
Figure D-3. UTP Cable Assembly.
BROWN
WHITE-BROWN
WHITE-BLUE
BLUE
DRAIN WIRE (ScTP ONLY)
GREEN
WHITE-GREEN
WHITE-ORANGE
ORANGE
CABLE
TIE WRAP
COLORS PER T568A
GROMMET
PIN 3
PIN 6
DRAIN
PIN 4
PIN 5
PIN 7
PIN 8
PIN 1
PIN 2
T568B
Summary of Contents for SCAN-LAN VI