144
SCAN-LAN VI
Table A-14. ISO 11801 Class C Pass/Fail Limits
Length
≤
100 meters
Characteristic Impedance
100±25
Ω
NEXT
Between 1 and 16 MHz, NEXT >ISO 11801
Class C Limits
Attenuation
Between 1 and 16 MHz, Attenuation <ISO
11801 Class C Limits
Split Pair
20 dB
Resistance
<9.9
Ω
Table A-15. ISO 11801 Class D Pass/Fail Limits
Length
≤
100 meters
Characteristic Impedance
100±25
Ω
NEXT
Between 1 and 100 MHz NEXT >ISO 11801
Class D Limits
Attenuation
Between 1 and 100 MHz, Attenuation <ISO
11801 Class D Limits
Split Pair
20 dB
Resistance
<9.9
Ω
Table A-16. ScTP Class C Pass/Fail Limits
Length
≤
100 meters
Characteristic Impedance
100±25
Ω
NEXT
Between 1 and 16 MHz, NEXT >ISO 11801
Class C Limits
Attenuation
Between 1 and 16 MHz, Attenuation <ISO
11801 Class C Limits
Split Pair
20 dB
Resistance
<9.9
Ω
Summary of Contents for SCAN-LAN VI