16
SCAN-LAN VI
2.2.2 C
ABLE
S
TANDARDS
S
UPPORTED TO
250 MH
Z
• TSB-67 Basic Link, CAT 5
• TSB-67 Channel, CAT 5
• ISO 11801 Class D
• ScTP Class D
• AS/NZS 3080 Class D
• BICC Millennium
• FTP 120 Ohms
• JIS X 5150
Two SCAN-LAN testers are required for 250-MHz tests and all Remote NEXT tests.
NOTE FOR USERS OF OLDER SCAN-LAN TESTERS
Firmware versions below 6.00 require factory calibration before running
250-MHz tests. Contact Black Box for factory-calibration details.
Cable Grading is not available for firmware versions 6.00 B3/B4 or
higher. Cable grading has been superseded by headroom and link-
performance analysis detail screens.
2.2.3 N
ETWORK
S
TANDARDS
S
UPPORTED AT
250 MH
Z
• IEEE 100BASE-Tx
• ANSI X3T9.5 TP-PMD
• ATM 155 Mbps
2.2.4 S
PECIAL
F
EATURES OF THE
SCAN-LAN VI
• Test reports can be saved in three different formats:
- Encrypted tamper-proof Report Manager format.
- Comma Separated Variable for import into spreadsheet programs.
- Text files for import into word-processing programs.
• Stores results of up to 450 Autotests.
• Graphical user interface on the main and remote units, allowing test
results to be viewed at both ends.
• Backlit LCD display.
Summary of Contents for SCAN-LAN VI