59
CHAPTER 6: Cable Test Descriptions
4. Press ENTER. Press ESC to abort the test. (Press the arrow keys to select
another cable test standard.)
6.9 Impedance
The SCAN-LAN VI does not have impedance.
6.10 Cable Toner
The Cable Toner function injects an audible frequency signal on a cable to
enable cable identification by a cable toner probe.
A modulated ~1 KHz signal is injected on pin one (1). Any commercially
available Toner Probe can be used to identify the corresponding cable end
in a remote wiring location.
R
UNNING
C
ABLE
T
ONER
1. Connect one end of the cable under test to the SCAN-LAN VI.
2. Set the dial to EXTENDED FUNCTIONS.
3. Press the arrow keys to highlight CABLE TONER.
SEND GRAPH DETAIL SAVE
POWER SUM NEXT
F1
F2
F3
F4
1,2
PASS
3,6
PASS
4,5
PASS
7,8
PASS
F1
F2
F3
F4