94
SCAN-LAN VI
Test Results
Possible Solutions
The length test
If the remote unit is connected during the length test, the
reveals OPEN
remote creates an OPEN in order to measure the length.
If the cable was terminated during the test, the SCAN-LAN VI
could not measure length.
If you are concerned about continuity, perform a Wire Map test.
Length exceeds
Compare measured values with expected values.
the specification
Make sure the NVP is correct by calibrating the unit to the cable.
Adjust the length of the cable as necessary.
Length is double
Check the termination of the cable.
what it should be
If the cable is not connected to the remote unit, the termination
hardware may automatically loop back pins (IBM Type A
connectors work this way, for example). Thus, the length is
twice the distance of the cable.
Length says
Perform a Wire Map test on the segment.
<5 feet when the
cable is longer
If Wire Map shows all pairs are OPEN or SHORT, the SCAN-
LAN Vt cannot detect the remote unit. Thus, all pairs
are OPEN or SHORT within 5 ft. of the SCAN-LAN VI.
If Wire Map results report that all wires are straight-through,
re-run the Length test.
Measured lengths
Some variation (plus or minus a few percent) is normal because
of wire pairs in the of the way wire pairs are twisted together in a UTP cable.
same cable are
different