6 - Parameter Descriptions
67
PFN 00
Jump to Parameter
LCD / LED
Displays
PFN: Jump Code
00 1
Description
By changing the value of this parameter and pressing [ENTER], you can jump directly to any parameter within
that group.
PFN 01 / P18
Open Field Trip Time
LCD / LED
Displays
PFN: Open Field T
01 1.0
sec
Range
Off, 0.1 – 90.0 seconds (Default: 1.0)
Description
The Open field trip time parameter sets how long before the controller will trip if an open field is detected during
starting.
NOTE:
If the motor is still spinning and a start is attempted, the unit may trip on open field.
NOTE:
Brush type motor only, (FUN 09 / P39) set to "Field Type".