48
Frame Operation and IP Network Setup
TCP/UDP Port Usage
From iControl to multiviewer
Between multiviewer and remote control panel
The following ports, used for communications to/from RCP-200 and Kaleido-RCP2 control
panels, are open by default on all Kaleido Software systems:
8085
TCP
Internal communication
8086
TCP
Internal communication
8087
TCP
Used for debugging purposes
8090
TCP
Web service
32769
TCP
filenet-rpc
5120
UDP
On multicast 230.8.8.9 for RCP2
7572
UDP
On multicast 230.8.8.8 for “keep-alive” (heartbeat)
7571
UDP
For “keep-alive” (heartbeat)
Port
Used for
Transport Notes
4160
Java Jini
TCP
Responsible for discovery and communications between
devices/services on a network.
32768–
65535
Java RMI
TCP
Remote Method Invocation (client/server
communication). Dynamic Allocation of ports. Required
for communication between client and Application
Server. This range can be restricted to match specific
security requirements. A minimum of 4000 ports should
be allocated.
Port
Used for
Transport Notes
5120
RCP2
TCP
Used to listen for Kaleido Software discovery packets
10000
TCP
For RCP2 protocol
10001
TCP
For RCP2 protocol
5120
UDP
On multicast 230.8.8.9 for RCP2 protocol
5121
UDP
For RCP2 protocol
80
HTTP
TCP
Used by the RCP-200 to obtain information from the
multiviewer’s system database
13000
TCP
Used by the RCP-200 to control the multiviewer via the
gateway
Port
Used for
Transport Notes
Summary of Contents for Grass Valley KALEIDO-X16
Page 20: ...20 Overview Functional block diagrams...
Page 26: ...26 Installation CompactFlash...
Page 42: ...42 Multiviewer Cabling Enabling EDID Auto Detection from the Monitor Wall...
Page 126: ...126 Configuring a Kaleido X16 Cascade Limitations...
Page 151: ...151 Kaleido X16 Hardware Description Installation Manual...