Frame Operation and IP Network Setup
Networking Essentials
The LEDs on the front of the frame (behind the cover) indicate the following conditions
depending on their color and whether they are blinking or not:
Networking Essentials
The following network prerequisites must be met:
• Any multiviewer you wish to configure or access by using XEdit or XAdmin must be
connected to an Ethernet switch.
• A client workstation must be connected to the LAN or Ethernet switch to access the
multiviewer by using XAdmin or XEdit.
• The Ethernet switch must support 100 Mbps full-duplex connections.
• The port on the Ethernet switch to which the multiviewer is connected should be
configured to auto-negotiate. By default, multiviewers have their Ethernet ports set to
auto-negotiate. If a switch does not support auto-negotiation, the recommended
settings are 100 Mbps, full-duplex.
LED
LED Status
Green
Blinking
green
Red
Blinking red Yellow
Blinking
yellow
Off
CPU
Normal
operation
Application
booting
Error
Live Update OS Booting
N/A
Front cover
is closed
CPF Activity N/A
Activity
N/A
N/A
N/A
N/A
No Activity
Video Inputs Inputs are
locked
N/A
Inputs are
unlocked, or
no input
ERROR ON
SIGNAL
N/A
N/A
Front cover
is closed
DVI Inputs
Inputs are
locked
N/A
Inputs are
unlocked, or
no input
ERROR ON
SIGNAL
N/A
N/A
Front cover
is closed
LTC
LTC valid
N/A
No signal
N/A
N/A
N/A
Front cover
is closed
Ref. Input
Input is
locked
N/A
Input is
unlocked, or
no input
ERROR ON
SIGNAL
N/A
N/A
Front cover
is closed
SDTI
Inputs are
locked
N/A
Inputs are
unlocked, or
no input, or
no SDTI
signal
ERROR ON
SIGNAL
N/A
N/A
Front cover
is closed
Gen. Status
System OK
Intrusive
self-
diagnostic
finished
Configuratio
n Failed,
Safe Mode
Firmware
Upgrading
Boot up
Diagnostic
(Verbose
switch on)
Firmware
error
Front cover
is closed
Severity
Boot OK
Booting
Boot error,
Need live-
update
Fatal error,
CALL TECH
SUPPORT
N/A
N/A
No power
Summary of Contents for Grass Valley KALEIDO-X16
Page 20: ...20 Overview Functional block diagrams...
Page 26: ...26 Installation CompactFlash...
Page 42: ...42 Multiviewer Cabling Enabling EDID Auto Detection from the Monitor Wall...
Page 126: ...126 Configuring a Kaleido X16 Cascade Limitations...
Page 151: ...151 Kaleido X16 Hardware Description Installation Manual...