Fan Rotation Valve
The fan rotation valve controls ON/OFF of the
gear motor of the radiator fan.
1
ya683b-001
Fan Rotation Valve_001
1
Solenoid valve
Inspection of Solenoid
Disconnect the solenoid connectors.
The normal resistance between the
connector terminals of the solenoid is
about 8.57
Ω
.
Solenoid Specifications
Voltage
Resistance
Holding
current
DC 12 V
8.57
Ω
1.4 A
■
1.
2.
■
Power Relay
Reel Rotation Relay
The reel rotation relay controls the rotation of
the reel with the power relay [MR5A602A1K]
(gray) by the operation of the reel rotation
switch and the proximity sensor of the Mower
Units #1/#3.
1
2
yx4wjg-001
Reel Rotation Relay_001
1
Power relay [MR5A602A1K (gray)]
2
Power relay [MR5A411A1K (brown)]
Inspection of Power Relay
Remove the power relay.
The normal measured resistance between
relay terminals 1 and 2 is about 75
Ω
.
2
1
4
3
6
5
2
5
6
1
4
3
38jyg3-004
Inspection of Power Relay_001
■
1.
2.
Elec
trical sy
stem
LM2700
Electrical system
Page 6-25
Electrical components
Summary of Contents for LM2700
Page 1: ...5 Unit Fairway Mower Service manual Serial No 10101 Ver 1 0...
Page 4: ...LM2700 Contents...
Page 10: ...LM2700 Safety Page 1 6 Safety Signs and Instruction Signs...
Page 11: ...Waste Disposal Page 2 2 About the Waste disposal Page 2 2 Disposal LM2700 Disposal Page 2 1...
Page 28: ...LM2700 Maintenance standards and maintenance Page 3 16 Greasing...
Page 194: ...LM2700 Electrical system Page 6 46 General inspection and repair...
Page 248: ...LM2700 Main body Page 7 54 Inspection and repair of each section...
Page 306: ...LM2700 Troubleshooting Page 9 14 Relating to Operating Machine and Mower Unit...
Page 324: ...LM2700 Reference Page 10 18 RT mechanical brake manual...