Deploying Avaya IP Office™ Platform IP500 V2
Page 199
15-601042 Issue 30j (18 May 2015)
IP Office™ Platform 9.1
Comments on this document? [email protected]
System Components: IP500 Base Cards
13.2.3 ATM Combination Card
These cards are used to add a combination of ports to an IP500 V2 control unit. Not supported by IP500 control units.
The newer IP500 ATM Combination Card V2 version is supported by IP Office Release 8.1 Feature Pack 1 and higher
only.
·
Supports
·
10 voice compression channels. Codec support is G.711, G729a
and G.723 with 64ms echo cancellation. G.722 is supported by
IP Office Release 8.0 and higher.
·
6 Digital Station ports for supported
Avaya DS digital telephones
(except 3800 and 4400 Series).
·
2 Analog Extension ports.
·
4 Analog Trunk ports:
Depending on the version of combination card, V1 or V2, the
analog trunk daughter card is equivalent to an
IP500 Analog
Trunk Card 4
V1 or V2 respectively.
·
Maximum per Control Unit: 2 combination cards of any type per
IP500 V2 control unit.
·
IP500 Trunk Card Support:
1. The trunk daughter card is pre-
installed and cannot be replaced with another card type.
·
IP Office Software Level: 6.0+.
This depends on the version of the card as follow:
·
V1: 6.0+. New build PCS04 cards are only supported in systems
running IP Office Release 6.1(20), 7.0(12) or 8.0 and higher.
Refer to IP Office Technical Tip 237.
·
V2: IP Office Release 8.1 Feature Pack 1 or higher.
Port Type Ports
Features
Digit
Station
1 to 6
Provides
DS
ports for supported
Avaya DS digital telephones
(except 3800 and 4400
Series).
LEDs
·
Green Flashing = Phone detected.
·
Green On = Phone active.
·
LED1 is also used for base card status:
·
Red On = Error
·
Red Slow Flash = Initializing.
·
Red Flash every 5 seconds = Card okay.
·
Red Fast Flash = System shutdown.
Analog
Phone
7 to 8
·
Supports ICLID modes DTMFA, DTMFC, DTMFD, FSK and UK20.
·
REN 2 (1 for external bell device).
·
Off-Hook current: 25mA
·
Ring Voltage: 40V.
·
Intended for connection to two-wire analog phones, the ports do not include a ringing
capacitor. For connection to 4-wire analog phones, connection should be via a master socket
with ringing capacitors.
·
During power failure extension port 8 is connected to the analog trunk port 12.
·
No status LEDs are used for analog phone extensions.
Analog
Trunk
9 to 12
·
DTMF, ICLID and busy tone detection.
·
Over-voltage/lightning protection (may still require
additional protection equipment
).
·
DTMF and LD (loop disconnect) dialing.
·
Echo cancellation.
LEDs
·
Green on = V1: Card installed. V2: Line connected to the port but idle.
·
Green flashing = Line in use.
·
LED 9 is also used for daughter card status.
·
Red On = Error
·
Red Slow Flash = Initializing.
·
Red Flash every 5 seconds = Card okay.
·
Red Fast Flash = System shutdown.
39
210
353
39
36