140
© 2019, ATEÏS, member of PAX ProAV Group
How to setup the monitoring for all zones:
1. Press [Global Get reference] to get reference.
2. If the variation of impedance measurement on [Realtime] field is big due to the unstable
environment or condition, users can manually define the tolerance value for each zone to
detect a bad impedance fault
The references should be taken only on zone with the connected speaker lines. Otherwise,
the zone will be open.
5.1.11.2.2 Monitoring settings of zone (A/B zone)
1. Zone: Indicate the number of zone.
2. Watt@1kHz/manual: Display the wattage value when the zones are connected to the
loudspeakers or define the value manually.
3. Enable: Enable/disable the zone monitoring. If the monitoring of a zone is disable, the
BOUTIQUE will not detect the faults of that zone.
4. Type/group ID--EOL size:
Type: Choose the hardware installation of VA-EOL/SL-SENSOR2/SL-SENSOR4 (3-wire or
A/B zone), see the wiring from
o
A/B zone: Each speaker line is A/B zone line detection.
o
EOL 3w-2c: SL-SENSOR2 (3 wire speaker line short sensor, 2CH).
o
EOL 3w-4c: SL-SENSOR4 (3 Wire speaker line short sensor, 4CH).
o
EOL A/B Zone: VA-EOL (End of speaker line module for multi-branch/AB Zone).
Group ID: Set the ID (0~3) of the connected SL-SENSOR2/SL-SENSOR4.
EOL---size: Choose the quantity of VA-EOL board which has connected in a zone (max.