Configuration
117
© 2019, ATEÏS, member of PAX ProAV Group
2. To fulfill the accuracy of RAC 5/8 calibration, please rotate the source selector knob on RAC
5/8, and record the current impedance value of every step displayed on [Now].
3. Then manually set the range of Level1~5/Level1~8 by using the formula ( Level 2)/2.
o
Example-1: If the current impedance value of 1-step and 2-step on RAC 5 are 25 and 57,
then set the Level 1 of RAC 5 as 0~
41 (25+57/2).
o
Example-2: If the current impedance value of 3-step and 4-step on RAC 5 are 45 and 61,
then set the Level 2 of RAC 5 as 42~
53 (45+61/2)
.
4. Follow Step 3 and calibrate the rest of the level value for Level1~5 (RAC 5) or Level1~8 (RAC
8).
5.1.8.2.4 Relay outputs
There are 4 logic relay outputs on BTQ-VM4 and 8 on BTQ-VM8/SG8/SL8, these outputs can be
programmed to open or close the contact for signaling the external system.
Set the default state (open or close) of logic relay outputs after the BTQ-VM4/VM8/SG8/SL8 is
powered.
5.1.8.3
Paging
The system will build the default Singular paging events including MSG TEST, ALERT, EVAC,
FIREMAN, MIC etc. for the first connected main controller. See the picture below.