5. Reference: Select the devices either all the BTQ-VM4/VM8/SG8/SL8 units (global-net) or the
selected BTQ-VM4/VM8/SL8 units (local-net) from drop-down box.
Global (global-net):
6. Get: Get all the reference of impedance value on all the BTQ-VM4/VM8/SG8/SL8
units (global-net).
7. Clear: Clear all the reference of impedance value on all the BTQ-VM4/VM8/SG8/SL8
units (global-net).
8. Clear fault: Clear the fault state of all zones on BTQ-VM4/VM8/SG8/SL8 units (global-
net).
BOUTIQUE device (local-net):
6. Get: Get the reference of impedance value from the selected BOUTIQUE local-net
system (BTQ-VM4/VM8/SL8), see the picture below.
7. Clear: Clear the reference of impedance value from the selected BOUTIQUE local-net
system (BTQ-VM4/VM8/SL8).
8. Clear fault: Clear the fault state of selected zones on BOUTIQUE local-net system
(BTQ-VM4/VM8/SL8).
In the case of zone short-circuit, the main controller/secondary unit will open the internal
relay to stop the output of the audio signal to speaker. After the relay is opened, the
controller/secondary unit cannot monitor and detect whether the problem is solved or
not. Therefore, after this problem has been solved, users needs to reset the monitoring to
close the relay to the output audio signal to the speaker and monitor the speaker line
again.
How to setup the monitoring for one zone:
1. Press [GET] button on the selected zone.
2. If the variation of impedance measurement on [Realtime] field is big due to the unstable
environment or condition, users can manually define the tolerance value to detect a bad
impedance fault. See the picture below.