Publication No. 980938 Rev. K
Model T940 User Manual
Astronics Test Systems
Soft Front Panel Operation 5-17
Table 5-13: Group Slew Attribute Settings
Setting
Description
Fast
Fast recommended for low voltage swings and fast data rates.
Med
Medium
Slow
Slow
Def
Default
Low
Low recommended for high voltage swings and low data rates.
The slew attribute is updated immediately when changed.
The relevant VXI
plug&play
API function is:
•
tat964_setGroupAttribute
OC Src
This numeric entry specifies the over current source setting in mA for the
selected group.
The over current source valid range is 10mA to 85mA.
The OC Src attribute is updated immediately when changed.
The relevant VXI
plug&play
API function is:
•
tat964_setGroupAttribute
OC Sink
This numeric entry specifies the over current sink setting in mA for the selected
group.
The over current sink valid range is 10mA to 85mA.
The OC Sink attribute is updated immediately when changed.
The relevant VXI
plug&play
API function is:
•
tat964_setGroupAttribute
Update Group Settings
This command button is disabled (dimmed) until any of the following group
attributes are modified:
•
Offset
•
IO Min
•
IO Max
When enabled (un-dimmed) this button programs the offset, IO min and IO max
group attributes.
The relevant VXI
plug&play
API function is:
•
tat964_setGroupAttribute