Publication No. 980938 Rev. K
Model T940 User Manual
Astronics Test Systems
Advanced Topics 8-3
Figure 8-1: Configure Module Panel
On this panel, six signals are set up to be coupled between Sequencers A to
B in the directions shown:
•
Error
•
Pass Valid
•
DRM Sync
•
Driver Disable
•
Halted
•
Static Pulse
These six are all of the signals that are potentially useful. Those that are not
needed may be excluded. For example, Static Pulse may be excluded if
channels will not be used in Static Mode anywhere in the DRS.
The panel automatically handles the direction and sense of these signals,
thus the Direction and Invert fields are dimmed.
Note: Sequence Reset and Master Reset are automatically handled in the
S/W, i.e. a Sequence or Master Reset on either Sequencer will reset the
other when they are linked.