Model T940 User Manual
Publication No. 980938 Rev. K
Soft Front Panel Operation 5-114
Astronics Test Systems
Setting
Description
Entry Condition
5. Active step: User
6. Pattern Memory: Free
IDLE
1. Idle Active: true
2. Sequence Active: false
3. Halt flag: false
4. Paused flag: false
5. Active step: User
6. Pattern Memory: Busy
“execute idle”, “last
step/stop idle finish mode”
ACTIVE
1. Idle Active: false
2. Sequence Active: true
3. Halt flag: false
4. Paused flag: false
5. Active step: User
6. Pattern Memory: Busy
“execute”, “resume”
HALT
1. Idle Active: false
2. Sequence Active: true
3. Halt flag: true
4. Paused flag: false
5. Active step: User
6. Pattern Memory: Free
“halt”
PAUSE
1. Idle Active: false
2. Sequence Active: true
3. Halt flag: false
4. Paused flag: true
5. Active step: User
6. Pattern Memory: Busy
“pause”
The following table describes the state transitions and the execute panel control
to perform it.
Table 5-85: Execute State Transition Description
Transition
Description
Soft Front Panel Control
pon
Power on
NA
reset
Sequencer reset
•
Depress
Reset
command
button.
•
Depress
Master Reset
command button (also disables
output drivers).
execute idle
Execute idle sequence
•
Enter step number and
depress
Execute
Idle
command button.
execute
Execute sequence
•
Enter step number and
depress
Execute
command
button.