Publication No. 980938 Rev. K
Soft Front Panel Operation 5-126
Astronics Test Systems
Figure 5-66: Static Data Panel
The static data panel contains controls that program the static timing and
stimulus data and displays the current static response data.
Prior to sequencer revision 0.21, the static timing uses the pulse generator to
specify the stimulus delay and the response delay for all the static channels to
within 15ns. Both delays are with respect to the start of a sequence.
Sequencer revision 0.21 and later uses a dedicated timing source that specifies
the response delay from 0 to 6.5ms. Stimulus delay is no longer supported.
Stimulus Delay
This control sets the delay from the start of a sequence execution to when the
stimulus pattern will be output and is only available in sequencer revisions prior
to 0.21.
The delay can be set from 20ns to 40s with 10ns resolution.
Note: The Stimulus Delay must be less than the Response Delay.
The relevant VXI
plug&play
API function is:
•
tat964_setStaticTiming
Response Delay
Prior to sequencer revion 0.21 this control sets the delay from the start of a
sequence execution to when the static pins will be sampled.
The delay can be set from Stimulus Delay + 10ns to Stimulus Delay + 40s with
10ns resolution.
Note: The Response Delay must be greater than the Stimulus