Model T940 User Manual
Publication No. 980938 Rev. K
Soft Front Panel Operation 5-54
Astronics Test Systems
1. Left click on the desired channel in the channel list control. A check mark
indicates the channel has been selected. Multiple channels can be
selected.
2. Use the pull down list box to select the desired channels and press the
Select
command button. The choices include:
•
None – De-selects all channels.
•
DRA – Selects CH1 through CH32.
•
DRB – Selects CH33 through CH64.
•
DRA & DRB – Selects CH1 through CH64.
•
Group 1 – Selects group 1 channels (DR4 CH1 through CH16)
•
Group 2 – Selects group 2 channels (DR4 CH17 through CH32)
•
Group 3 – Selects group 3 channels (DR4 CH33 through CH48)
Channel Parameters
The channel parameters consist of:
•
Stimulus Signal
•
Stimulus Format
•
Capture Signal
•
Capture Mode
•
Static Mode
After any of the channel parameters have been changed, the
Update
command
button must be depressed in order for the new channel settings to be
programmed.
Stimulus Signal
This pull-down control programs the drive phase timing for the selected
channel(s) stimulus signal.
The selections for this pull-down control are:
Table 5-55: Stimulus Signal Settings
Setting
Description
Phase 1
Use phase 1 timing signal to control output
driver timing.
Phase 2
Use phase 2 timing signal to control output
driver timing.
Phase 3
Use phase 3 timing signal to control output
driver timing.
Phase 4
Use phase 4 timing signal to control output
driver timing.