Astronics Test Systems
Soft Front Panel Operation 5-71
Setting
Description
ECLTRG0,1
Source set to VXI ECL trigger
TTLTRG0-7
Source set to VXI TTL trigger
LTB0-7
Source set to Linked Trigger bus signal
Connect State
This control allows the user to open or close the isolation relay.
DR2 and DR7 Driver/Receiver
boards do not have isolation relays.
The relevant VXI
plug&play
API function is:
•
tat964_setAuxConnect
Note: DR2 and DR7 Driver/Receiver boards do not have relay isolation.
Properties (Programmable Logic)
This command button displays the panel to allow the user to configure the
Programmable AUX Driver/Receiver
settings. Refer to
Configure Channel
Properties
, earlier in this chapter, for control descriptions for this panel.
The relevant VXI
plug&play
API functions are:
•
tat964_setAuxSourceLevels
•
tat964_setAuxSourceParameters
•
tat964_setAuxSlewRate
•
tat964_setAuxSenseLevels
•
tat964_setAuxSenseParameters
•
tat964_setAuxLoadState
ECL Mode (ECL Differential or Bipolar Logic)
This control allows the user to select the ECL mode.
Table 5-69: ECL Mode Settings
Setting
Description
Bipolar
AUX configured as bipolar ECL.
Differential
AUX configured as differential ECL
The relevant VXI
plug&play
API function is:
•
tat964_setAuxEclMode
Logic Mode (LVTTL/Bipolar ECL Logic)
This control allows the user to select the LVTTL/ECL mode.