Model T940 User Manual
Publication No. 980938 Rev. K
Soft Front Panel Operation 5-132
Astronics Test Systems
Error Address Display
The Error Address memory display is accessed from the
Execute > DSx > View
> Results
menu bar selection and setting the
View
control to
Errors Address
.
(Where “x” is the sequencer you wish to query.)
Figure 5-70: View Errors Address Panel
The error address memory records the sequence step and pattern address of the
first 1024 errors of a sequence execution and is displayed in the
Step #
and
Addr
columns. The
Pattern
column is calculated based on the
Record Type
setting and
Record
column is read from the record memory.
The relevant VXI
plug&play
API function for
Step #
and
Addr
data is:
•
tat964_queryErrorAddress
The relevant VXI
plug&play
API function for
Record
data is:
•
tat964_queryRecordData
The relevant VXI
plug&play
API function for
Pattern
data is:
•
tat964_queryPatternSet (if
Record Type
set to Normal)
•
tat964_queryRecordIndex (if
Record Type
set to Indexed)
The View menu selection allows the address column of the error address panel
to toggle between decimal and hexadecimal.