Setting
Description
Step Fail
Halt the current sequence at the end of
the next sequence step if the pass/fail
flag is set to fail.
Sequence Fail
Halt the current sequence at the end of
the next sequence if the pass/fail flag is
set to fail.
Pattern Pass
Halt the current sequence at the end of
the next pattern if the pass/fail flag is set
to pass.
Step Pass
Halt the current sequence at the end of
the next sequence step if the pass/fail
flag is set to pass.
Sequence Pass
Halt the current sequence at the end of
the next sequence if the pass/fail flag is
set to pass.
The relevant VXI
plug&play
API function is:
•
tat964_setHaltMode
Finish Mode
This pull-down control programs the finish mode. When a sequence execution
completes, the sequencer will enter either the
Standby
or
Idle
state. The
Standby
state outputs the first pattern of the specified step and pattern memory
can be accessed by the user while the sequencer is in Standby. The
Idle
state
outputs the entire pattern set of the specified step and pattern memory cannot be
accessed while the sequencer is idling.
The selections for this pull-down control are:
Table 5-88: Finish Mode Settings
Setting
Description
Standby
Go to
Standby
after sequence
completes.
Idle
Go to
Idle
after sequence completes.
The relevant VXI
plug&play
API function is:
•
tat964_setFinishSequence
Finish Mode Step
This control sets the finish mode step number.
The relevant VXI
plug&play
API function is:
•
tat964_setFinishSequence